Synopsis
HVAC School is the ever growing online source for real training topics for technicians in the Air-conditioning, Heating and Ventilation Fields. In the podcast, we will share recorded training, tech ride alongs, share challenging diagnostic scenarios. All to help make the industry, your company, and your truck a better place to be.
Episodes
-
The Future of Refrigerants is Here With Opteon XL41
09/03/2023 Duration: 34minIn this podcast from AHR 2023, Brandon Marshall from Chemours and Chris Forth from JCI talk about the future of refrigerants and Opteon XL41 (R-454B). Refrigerant regulations are changing to pave the way for lower-GWP refrigerants, but M1 is also in full swing. M1 refers to the U.S. Department of Energy's implementation of the new efficiency standards for A/C units and heat pumps (SEER2, EER2, etc.). These standards changed the equipment testing procedure to match field conditions more closely. Opteon is the next-generation portfolio of low-GWP refrigerants for Chemours as a successor to the legacy refrigerants in the Freon product line. These refrigerants are a response to the HFC phasedown outlined in the AIM Act. JCI chose to use Opteon XL41, an HFO, for its equipment due to Opteon XL41's low GWP compared to R-32 and because of the similar operating pressures and temperatures to R-410A. A2Ls are a permanent change in the industry, and their safety considerations and best practices are here to stay. However
-
MeasureQuick is EXPLODING with Jim & Joe
07/03/2023 Duration: 35minIn this podcast from AHR 2023, Jim Bergmann and Joe Medosch talk about measureQuick and the ways it's EXPLODING with growth and new features. They also talk about heat pumps, electrification, and other hot topics in the industry. Jim Bergmann recently released an open letter about heat pumps on LinkedIn; he addressed the shortcomings of the industry from a skill standpoint. The lack of training and standards may be mitigated with proper training (and an understanding of building science fundamentals) or by embracing hybrid systems. Heat pumps may also perform relatively poorly during extreme weather events and may not manage temperature swings well. MeasureQuick has recently been working with ACCA and formed other partnerships to allow for standardization (for companies and the industry as a whole). More companies are also integrating with measureQuick, especially TEC and their TrueFlow Grid; accuracy across brands tends to be pretty consistent, and measureQuick allows you to mix and match tools. The customer
-
Infiltration Skeletons Behind Closed Doors w/ Genry
02/03/2023 Duration: 47minGenry Garcia returns to the podcast to talk about pressures in the building envelope, namely the infiltration skeletons behind closed doors. When doing load calculations (Manual J), we need to know how much of the heat load, especially the latent heat load, comes from leakage in the building envelope and the ducts. Opening/closing doors and windows can also worsen the issues that stem from infiltration due to upsetting the balance of pressures in the home. Smoke pencils and other similar tools can give you an idea of the pressure in a home and how it could change when doors open or close. Since there is a lot of room for inaccuracy in extreme climates (especially those with high latent loads), many HVAC systems are oversized and underperform. Some building design features also exacerbate problems presented by oversized HVAC systems. To get the data we need to design systems that mitigate those issues, we need to do a blower door test. Downsizing the tonnage in retrofits or replacements usually has advantages,
-
Understanding Leak Detectors With Inficon
28/02/2023 Duration: 30minIn this episode recorded live at AHR Expo 2023, Nick from INFICON joins Bryan to talk about leak detectors and how we can improve our understanding of them. Some leak detectors, including the INFICON Stratus, measure concentrations in PPM (parts per million). When measuring PPM, we have to keep in mind that it doesn't indicate the size of the leak or leak rate, but it does help us pinpoint the leak location. In some cases, we also have to watch for automatic zeroing capabilities. Leak detectors come in many varieties, including heated-diode, ultrasonic, and infrared; each type has unique maintenance needs. Heated-diode leak detectors are sensitive, but their sensors wear off with frequent use and will require replacement. Infrared leak detectors use infrared absorption and don't degrade over time the way heated-diode leak detectors do. An ultrasonic leak detector picks up the sound of refrigerant and air leaking out of a hole to pinpoint the leak. It's a good idea to approach leak detection with a plan, inclu
-
Making Cold Climate Heat Pumps Work w/ Copeland and White Rodgers
23/02/2023 Duration: 46minIn this episode recorded live at AHR Expo 2023, Dustin and Jim from Copeland/White-Rodgers join Bryan to talk about the use of heat pumps in cold climates. They talk about the history of heat pump innovation and talk about changes to come. Variable-speed and two-stage compressors, as well as advanced controls, make it easier for contractors to control sizing and for heat pumps to perform to acceptable standards in cooler climates. Contractors in cold climates also rely on dual-fuel models that use electric and gas heat, which makes it easier for the system to move the desired amount of heat. Variable-speed and two-stage compressors help the system deal with different heating and cooling capacities; in cooling mode, these technologies can also help with latent removal if the blower is also able to vary with the compressor. Advanced controls, especially universal controls, also help with defrost management, a key component of heat pump performance. When defrost is managed effectively, customers can yield energ
-
RTU Retrofits Facts and Considerations with JCI
21/02/2023 Duration: 20minIn this episode recorded live at AHR Expo 2023, Matthew from JCI (Johnson Controls) joins Bryan to talk about rooftop unit (RTU) retrofit facts and considerations. When doing an RTU retrofit, you want to make sure you know the budget before anything else; larger budgets will allow you to implement things like VFDs and even VAV technology. In many cases, you may consider adding an economizer for "free" cooling and energy savings. You also want to know what you will get out of a retrofit in terms of value, especially when it comes to system efficiency and longevity. Some common IAQ upgrades for RTUs include improved filtration, especially with MERV 13 filters. Economizers also allow you to control the amount of outside air with the help of an exhaust system or even barometric relief. UV lighting can also be used in light commercial RTUs. When doing a retrofit, you'll want to pay attention to the existing equipment's footprint. Sticking to that footprint will make the replacement aspect easier. The utility and e
-
Troubleshooting The Modern ECM
16/02/2023 Duration: 31minChris Mohalley returns to the podcast to talk about troubleshooting the modern ECM (or EC motor) and give diagnostic tips. ECMs are electronically commutated motors; they are mechanical motors with an electronic control module that dictates everything the motor does. As with all motors, ECMs have inputs and outputs. If the motor is not running, the first step is to check the line voltage and make sure that it is correct and connected continuously, as that's one of the main inputs on all ECMs; there is no relay or switch on the line side. The motor itself is the output, so you will know if the output is correct if the motor is rotating and generating airflow as intended. Constant-speed and constant-torque motors can all be diagnosed with a basic voltmeter. One of the most difficult parts of troubleshooting constant-torque ECMs is knowing how the taps are programmed by the manufacturer; reading the manual and schematic is advantageous during diagnosis, especially as these motors have evolved to use pulse-width
-
Training for the Future w/ Clifton & ESCO
09/02/2023 Duration: 40minClifton Beck of ESCO Group returns to the podcast to talk about training for the future. He also talks about how he became an educator, what it's like to be a trades educator with ESCO Group, and how educators can handle the recent HFC phasedown and the rise of A2L refrigerants. Especially with the COVID-19 pandemic, mass media has changed the way the industry thinks about training. Organizations like ESCO have evolved, and that is evident in their curricula; changes are being made to keep up with field tools and equipment to make sure technicians are up to date. A large network of industry experts makes these training curricula possible. Virtual and media education have changed the way we think of educators. Many of the most knowledgeable people in the industry, including people like Craig Migliaccio, work in the field and aren't traditional educators but have a large positive influence on the industry due to social media. Refrigerant regulation changes, including the HFC phasedown, present opportunities for
-
MERV vs. Motors
07/02/2023 Duration: 39minECM expert Chris Mohalley joins the podcast to talk about the balance between selecting air filtration and motor performance, also known as "MERV vs. Motors." As the industry realizes that filtration is more important, we're starting to see an interest in filters with MERV ratings of 13 or higher. However, there are some design challenges associated with static pressure drops across filters, motor responses to static pressure, and airflow. If the airflow isn't set properly, that could affect the refrigerant charge and temperature rise. PSC motors' performance directly follows the load; as static pressure increases, the airflow rate produced by the motor decreases. They may also make loud noises when the static pressure is high but satisfactory airflow. However, they are robust and don't typically fail quickly due to high static pressure. Electrically commutated motors (ECMs) are operated by electronic controls and come in constant torque or constant airflow varieties. The former has a performance curve (like
-
Effective Filtration & More w/ John Ellis
02/02/2023 Duration: 50minJohn Ellis, a business consultant who specializes in IAQ training, joins the podcast to talk about effective filtration, product development, and more. John has recently worked with an OEM to bring field practicality and application to the engineers who design products. Filtration design is a relatively poorly understood concept in the industry; we tend to overlook a filter's ability to remove particulates from the air when we prioritize static pressure drop. We have to understand how the duct design can make higher-MERV filters work and how the face velocity plays into design and comfort. John also talks about bypass HEPA filtration and its appropriate uses and potential for misapplication. Bypass HEPA may be integrated with the HVAC system (but run independently of the system) or installed independently of the HVAC; its effectiveness will be dictated by its runtime, and it doesn't filter everything. IAQ products and strategies need to produce quantifiable results, and our industry needs people to be traine
-
Do Houses Need to Breathe? w/ Allison Bailes
26/01/2023 Duration: 31minDr. Allison Bailes from Energy Vanguard joins the podcast to answer the age-old question: do houses need to breathe? He also talks about his new book, A House Needs to Breathe... Or Does It? You can purchase that book directly through the Energy Vanguard site at https://energyvanguardstore.com/ or on Amazon. HVAC professionals can benefit from learning about building science because there is a lot of overlap between the two, and an HVAC technician who knows about building science can set themselves apart in the market. In short, Dr. Bailes doesn't think a house needs to "breathe," especially if a house brings in low-quality air, especially humid air, through gaps and cracks. Some people also use the term "breathe" differently; some may be referring to leakiness, and others may refer to drying out a house. It is necessary for a house to be dry, but we want to make sure that fresh air is controlled. If you build a home tightly, you have to ventilate it correctly. We have to control air, liquid water, water vapo
-
What the Heck is High Performance HVAC w/ David Holt
19/01/2023 Duration: 46minDavid Holt with the National Comfort Institute (NCI) returns to the podcast to talk about high-performance HVAC and what the heck it even is. High-performance HVAC is all about delivering the highest possible equipment performance out of the box. High-performance HVAC is a key element of NCI's work; equipment should be able to deliver the health, comfort, safety, reliability, and efficiency expected by the occupants, and equipment that can't do that often has root issues we need to troubleshoot and fix. In many cases, the root cause has something to do with airflow issues. As contractors, we can focus more heavily on testing fan airflow to get to the bottom of poor HVAC performance, even when there may not be an apparent airflow problem. We need the proper test instrumentation to measure CFM, a key indicator of performance. We can't expect to maximize system performance until the airflow is correct across the heat exchange surfaces. Many factors that contribute to poor equipment performance actually have to
-
Setting Realistic Customer Expectations w/ Ed Janowiak
12/01/2023 Duration: 45minEd Janowiak returns to the podcast to talk about setting realistic customer expectations when designing residential HVAC systems across climates, seasons, and load conditions. Being honest and aggressive is one of the best ways to set realistic expectations, and our load calculations and equipment selection need to reflect that. Manual J calculations must consider non-design days, not just the design conditions, including partial load conditions. Partial load conditions that aren't accounted for may make it more difficult for the HVAC system to control latent heat, potentially leading to moisture problems indoors. We have to set expectations in the summer a bit differently than we set expectations in the winter, and we must account for the equipment type when we create expectations. Heat pumps perform differently than furnaces, and oversized furnaces typically present fewer problems than oversized heat pumps in areas with high latent loads. Clients must also be willing to acknowledge that systems won't perfo
-
Mini Split Install and Service Tips
03/01/2023 Duration: 50minCraig Migliaccio, aka AC Service Tech, returns to the podcast to share his knowledge about mini-split install & service. He also talks a bit about his upcoming book, “Inverter Mini-Split Operation and Service Procedures.” Mini-splits are unique because they are compartmentalized in ways that traditional central-air ducted systems are not. Mini-splits come in many varieties, including ducted and ductless types, as well as multi-zone types. Many are inverter-driven and have more electrical efficiency as a result and can vary their capacities based on load variation. Mini-splits have metering devices at their outdoor units, and these devices may be electric expansion valves (EEVs) or capillary tubes. Inverter mini-splits also don’t have filter driers because their PVE oil doesn’t have the same acid concerns as POE oil, and they don’t have traditional liquid lines. Flare connections are also critical when installing ductless systems, especially because you want systems to be tight to prevent leaking and cont
-
CO Doesn't Leak w/ David Richardson
29/12/2022 Duration: 38minDavid Richardson from NCI returns to the podcast to talk about why CO (carbon monoxide) doesn't leak and what it does instead. CO is a highly dangerous gas that is colorless and odorless, and we can keep ourselves safe by staying aware of it with personal low-level CO monitors. However, CO doesn't leak; it spills, especially via backdrafting, a blocked flue, or updrafting. Whenever the flue gas comes back inside the structure unintentionally, there is room for a potential CO problem. With proper testing, we can determine the cause of that spillage and make the best choice to stop it from happening. When there is an excessive draft, there's often turbulence in the draft hoods, which leads to spillage. Spillage commonly happens at the draft hood, but it can also happen near the burner compartment of a gas appliance. Smoke tests won't detect that, but CO testing will. However, we need to look for rising CO levels over the run cycle of the equipment. If you test CO levels in the ducts, you're only seeing how the
-
One HSI Furnace Control to Rule Them All w/ Jim Fultz
27/12/2022 Duration: 39minJim Fultz with Emerson White-Rodgers returns to the podcast to talk about one HSI furnace control to rule them all, the 50M56X-843 Universal Single Stage Integrated Furnace Control. The 50M56X does not come with wiring harnesses; the control comes with the plugs that the majority of manufacturers use, making it a versatile and user-friendly universal part. It also works with the White-Rodgers Connect app to help you configure the part with the burners. You can also do some basic configuration when it comes to the blower motor. With the 50M56X and Emerson White-Rodgers Connect app combination, you can quickly and accurately configure the control without wi-fi or a password. An igniter is included in the box with the 50M56X; the igniter must match the control. The control also comes with a three-digit display that communicates the microamp current from the flame sensor, meaning you don’t need to use a meter on the flame sensor. So, you can carry less truck stock and complete more calls with this universal part
-
Using Ice to Balance Energy Consumption
22/12/2022 Duration: 32minYaron Ben Nun from Nostromo Energy joins the podcast to talk about ice banking, a way of using ice to balance energy consumption. Nostromo Energy is an Israel-based company that has recently started working in California. Water has a very high latent heat of fusion, meaning it can absorb and store a lot of energy between its solid and liquid states of matter. By storing ice, Nostromo Energy can support commercial and industrial structures that utilize chiller-type applications by offering a clean and sustainable battery thanks to water and its physical properties. Load balancing or management will be critical as the electrification of heating sources continues. Lithium-ion batteries aren't sustainable solutions in many of these cases, and that's where ice banking can support the grid by providing a thermal battery. Water offers many advantages as a medium for storing energy, especially since it is natural and doesn't have the numerous economic and labor concerns that come with the production of many other bat
-
We need to Pay Better! - An Audio Manifesto
20/12/2022 Duration: 47minEric Kaiser and Ty Branaman return to the podcast to talk about why we need to pay technicians and field workers better in the HVAC industry and how small and medium businesses can help current employees. When the pay for entry-level HVAC positions can't compete with fast-food, retail, or warehousing jobs, we can't expect people to flock to the industry, especially since so much skill is required. Overtime is also almost unavoidable in many places, and it's a problem that requires a more nuanced solution than getting more trucks on the road. The tricky part about paying more for overtime is that it's challenging to implement pricing structures that charge the end user proportionally. As prices for equipment, fuel, and living essentials go up, the company often has to eat those extra costs if they want to pay their technicians fairly. In some cases, HVAC businesses feel bad for the customer when the cost of everything increases, which could be doing a disservice to the techs who deserve higher wages for their
-
Refrigerant Myth Busting w/ Dr. Chuck
15/12/2022 Duration: 38minDr. Chuck Allgood from Chemours returns to the podcast to do some refrigerant myth-busting. Many people don’t understand why high-GWP HFCs can impact the atmosphere if the refrigerant is heavier than air. High-GWP HFCs exist for a long time, and they last long enough for natural mixing and the wind to distribute their molecules throughout the atmosphere. HFOs, by comparison, are more reactive in the atmosphere and have relatively short lifespans, meaning they have less of an effect on the environment. Even though refrigerants with lower GWPs are entering the market, it’s always been our job to keep refrigerants inside the system where they can’t harm the environment. However, when leaks occur, these lower-GWP refrigerants break down quickly outside the system but not inside it. Contractors and manufacturers should still work together to reduce leak rates as much as possible, even as we keep innovating. Another common myth is around “natural refrigerants,” which are common in some forms of refrigeration, but “
-
The Good, Bad and Ugly of Trade Schools
13/12/2022 Duration: 45minTy Branaman and Eric Kaiser return to the podcast to discuss the good, the bad, and the ugly of trade schools. They cover the opportunities and challenges they've observed in trade schools. As with for-profit colleges, for-profit trade schools market programs aggressively and can take people who are at a crossroads in their life and saddle them with debt. In some cases, trade schools are hesitant to fail people and end up passing people who don't have the technical proficiency to be effective tradespeople. Sometimes, trade schools don't emphasize practical skills and contractors' experiences as much as they could, either. The tricky part about trade schools is their allocation of resources, which instructors typically can't control. Sometimes, too much money is spent on equipment, and not enough is spent on the instructors. There needs to be an appropriate balance of both in an effective program. Administrative distractions can also make programs less likely to produce effective technicians. The admission