HVAC School is the ever growing online source for real training topics for technicians in the Air-conditioning, Heating and Ventilation Fields. In the podcast, we will share recorded training, tech ride alongs, share challenging diagnostic scenarios. All to help make the industry, your company, and your truck a better place to be.

Episodes

  • Duct Smoke Detector Facts and Wiring - Short #203

    23/07/2024 Duration: 12min

    In this short podcast, Bryan answers a listener-submitted question about duct smoke detector facts and wiring. He focuses on Honeywell duct smoke detectors (namely the D4120W), but there are some general best practices that can be applied to most duct smoke detectors. The power supply may be 24v or 120v AC or DC and may have multiple inputs. You should not break that constant power source. There are also fan shutdown contacts, which may be normally open (alarm condition) or normally closed (non-alarm condition). Supervisory contacts open to indicate a trouble condition to the panel when something in the circuit isn't working properly (NOT an alarm condition). There is often a resistor at the end of the loop, and the alarm panel recognizes a specific resistance. Alarm initiation contacts close and create a shorted condition when there is an alarm condition (the supervisory contacts open if there is a trouble condition).  Smoke detectors in the ducts are different from the ones on ceilings; they usually shut do

  • Trust the NEW Process: Embracing Evolution in HVAC Technology

    18/07/2024 Duration: 38min

    In this episode of the HVAC School podcast, host Bryan and guest Jesse Stewart from NAVAC discuss the generational divide in the HVAC industry and the importance of embracing new technologies and processes. They explore the challenges faced by both experienced technicians who may be set in their ways and newcomers to the trade who need proper mentoring. Jesse emphasizes the importance of respecting traditional methods while making way for new techniques. He discusses how bad habits can be passed down from mentors to apprentices, highlighting the need for continuous learning and adaptation in the rapidly evolving HVAC industry. The conversation touches on the importance of treating apprentices with respect and providing them with educational experiences rather than just menial tasks. The podcast delves into specific HVAC practices, particularly focusing on evacuation and recovery processes. Jesse explains the significance of using proper tools and techniques, such as valve core removal tools, high-quality vacu

  • Soft Start & Solar - Short #202

    16/07/2024 Duration: 10min

    In this short podcast episode, Bryan dives into soft start & solar technology, which often work together. He also talks about how we can install ductless systems in homes that rely on solar power. Soft starts are NOT hard starts. Hard starts add more current to the start (auxiliary) winding, which creates a stronger phase shift. Instead, soft starts control the current on the start and run windings and provide just enough of a phase shift to ramp up the motor slowly; it provides a regulated power supply, which means that a slow startup doesn't necessarily cause overheating because there is no locked rotor condition. We can use soft starts on two-stage compressors but need to make sure the compressor goes up to high speed during the starting sequence. Soft starts "learn" the compressor's cycles, so we need to make sure they are trained to reach the high stage, not the low stage. In systems with multiple compressors, we need to have a separate soft start for each compressor. We don't need to use soft starts

  • Make Summer Work for You w/ Matt Bruner

    11/07/2024 Duration: 44min

    In this episode of the HVAC School podcast, host Bryan Orr welcomes Matt Bruner to discuss the concept of a "summer survival guide" for HVAC professionals. They explore strategies for maintaining work-life balance during the busy summer season and share personal experiences on prioritizing family and personal well-being while managing the demands of the HVAC industry. The conversation delves into the importance of intentional planning before the summer rush begins. Matt shares how he and his family implement practices like scheduling an end-of-summer vacation, utilizing daycare services, and outsourcing lawn care to create more family time. Bryan emphasizes the need for financial discipline, avoiding impulsive purchases, and instead investing in services that can alleviate stress and create more personal time. The discussion turns to the challenges of people-pleasing tendencies in the workplace and with clients. Both hosts stress the importance of setting boundaries, learning to say no, and prioritizing one's

  • How do Inverter Air Conditioners Work? - Short #201

    09/07/2024 Duration: 10min

    In this short podcast episode, Bryan answers a listener-submitted question: How do inverter air conditioners work? Inverter-driven systems have variable capacity to match loads. We can provide cooling or heating BTUs to match the needs of the space without overcompensating or undercompensating and causing temperature swings. Load matching also helps us get better efficiency out of the system. High-humidity climates also benefit from load matching, as equipment doesn't dehumidify well unless it has been running the entire time. When set up and designed properly, variable frequency drives (VFDs) improve comfort, efficiency, and even dehumidification. You can "overclock" your compressor to get more BTUs out of it without oversizing, particularly when you have high heating loads due to the cold weather. Inverter-driven equipment takes AC power in, runs it through a rectifier circuit, and turns it into rough power that resembles DC power. The current is then smoothed out and goes through the inverter bridge circui

  • How to Size Dehums w/ Tim De Stasio

    04/07/2024 Duration: 51min

    In this episode of the HVAC School podcast, host Bryan Orr interviews Tim De Stasio, an experienced HVAC practitioner and consultant. Tim shares his journey in the HVAC industry, from his early days in vocational school to running his own contracting business for 12 years. He now focuses on consulting, design, and contractor training, allowing him to pursue his passion for HVAC while sharing his knowledge with others. The conversation delves deep into the world of dehumidifiers, exploring their importance in modern HVAC systems, especially in humid climates. Tim emphasizes the need for supplementary dehumidification in many homes, particularly during part-load conditions when air conditioning systems may not effectively control humidity. He explains the process of selecting and sizing dehumidifiers, stressing the importance of considering factors such as peak latent load conditions, actual dehumidifier performance under real-world conditions, and static pressure effects on output capacity. The discussion also

  • Teaching Communication Confidence - Short #200

    02/07/2024 Duration: 07min

    In this short podcast episode, Bryan shares some strategies for teaching communication confidence, which may come in handy if you have newer techs who feel nervous or struggle to communicate with other people. The main way to build confidence is to get them to talk in the first place. Scripts and roleplay scenarios during training can help get people used to speaking and give them a reference. Whether we're in sales or not, we have to share information and complete business transactions. Roleplaying those conversations in a controlled, familiar setting allows your more timid team members to put in the reps. The youngest generation in the workforce tends to be exceptionally uncomfortable talking compared to others; they often prefer to communicate via text. These techs can learn a lot from spending time with customer service representatives (CSRs), especially in difficult situations with upset clients. Then, you can address the non-verbal cues that also play a massive role in in-person communication. At Kalos,

  • Using Refrigerant Troubleshooting Charts w/ Joey Henderson

    27/06/2024 Duration: 55min

    This episode focuses on understanding and effectively utilizing various refrigeration system charts and measurements for troubleshooting and diagnostics. Joey Henderson, an HVAC veteran and trainer, shares his wealth of knowledge and experience on this topic. Joey starts by discussing the challenges he faced early in his career when trying to make sense of the confusing charts with arrows indicating high, low, high head, low head, etc. He emphasizes the importance of knowing the "supposed to be" values before attempting any measurements or referencing charts. Without this baseline understanding, the measurements become meaningless. He then delves into specific measurements like subcooling, superheat, evaporator temperature/suction saturation, condenser split, and compressor amperage. For each measurement, Joey explains the ideal range, how to interpret deviations, and how different factors like humidity, airflow, and refrigerant type can affect these values. He also highlights the differences in approaches fo

  • Wiring in Condenser Fan Motors - Short #199

    25/06/2024 Duration: 15min

    In this short episode, Bryan talks about wiring in condenser fan motors, including aftermarket motor considerations and the different wire configurations. When condensing fan motors fail, we need to know what to use to replace them. We often use PSC motors, though in cases when we replace a motor with an ECM, we still need to match the horsepower despite the increased flexibility. The motors we typically keep on our truck are 1/3 or 1/6 HP motors.  Frame size (diameter) and depth also come into play; you may encounter a 42-frame motor or a 48-frame motor. You can't replace an 825 RPM motor with a 1075 RPM one because the poles are different (6-pole vs. 8-pole). Single-phase 208/230v will be the most common motors in residential systems, and the phase and voltage must match. You should also know how to reverse a motor if it is reversible. The bearing type will have some tradeoffs; ball bearings last longer but are louder than sleeve bearings.  3-wire and 4-wire condensing fan motors are essentially the same; t

  • Committing to HVACR Education w/ Copeland

    22/06/2024 Duration: 29min

    This podcast episode focuses on the critical shortage of HVACR technicians and installers across the industry. The hosts discuss the massive gap that exists, with estimates of nearly 200,000 open roles expected in the next few years. They are joined by Lenny Diaddario from Copeland's contractor services department and Chris Harris from the educational nonprofit National Coalition of Certification Centers (NC3). Lenny and Chris explain the various initiatives Copeland and NC3 have undertaken to help attract more people to the HVACR trades. This includes STEM education outreach to get kids interested from an early age, partnerships with organizations like SkillsUSA and PHCC, virtual reality training tools that allow interactive compressor teardowns, and comprehensive certification curricula developed in collaboration with subject matter experts and instructors. One major program they highlight is the "train the trainer" events where instructors from trade schools can get certified on the Copeland curriculum ove

  • The Chemistry of Combustion w/ Rachel Kaiser

    20/06/2024 Duration: 38min

    In this episode of the HVAC School Podcast, Bryan interviews Rachel Kaiser, a chemist with a passion for making science more accessible and understandable, especially when it comes to the topic of combustion. Rachel shares her background of how her family's restaurant business sparked her early interest in chemistry and the science behind mixing ingredients to produce desired results. Rachel dives deep into explaining the fundamental chemistry behind the combustion process. She breaks down the three key components required for combustion to occur - fuel, oxygen, and a heat source - and how the ideal chemical reaction is represented. However, she emphasizes that in the real world, factors like using natural gas (a mixture of gases) as fuel instead of pure methane and air (also a mixture) as the oxygen source lead to incomplete and imperfect combustion reactions. The discussion highlights the importance of combustion analysis and monitoring for byproducts like carbon monoxide (CO) and nitrogen oxides (NOx). Rac

  • Hoses / Types and Applications w/ NAVAC - Short #198

    18/06/2024 Duration: 16min

    In this short episode of the HVAC School podcast, Bryan talks about hoses and their various types and applications, particularly focusing on NAVAC hoses. Charging hoses (NAVAC: NH5 and NH5L) ideally shouldn't be longer than 5-6 feet, as the longer the hose, the more refrigerant it will hold. Manifold gauges also have leak points, so it's usually better to use probes instead of manifolds to help with charging. Charging hoses with ball valves (NH5S and NH5SC) can help you control the flow and are great for recovery. Whenever you use charging hoses, they will have a core depressor on one side only (usually the 45-degree side, if applicable); the right amount should be exposed, and the seal should be in good shape. Larger-diameter hoses with higher burst pressure are advantageous for recovery (though it's better to have separate hoses for recovery and evacuation). Larger-diameter hoses of a shorter length will allow you to get a higher flow rate, including cases where you have 1/4" connectors (though the F1028 &a

  • Have Fun With CRAC (Computer Room AC)

    13/06/2024 Duration: 51min

    In this episode of the HVAC School podcast, Bryan interviews Pat Ward, an HVAC technician who specializes in servicing and maintaining computer room air conditioning (CRAC) units for data centers. They dive deep into the unique challenges and setups involved in cooling these critical facilities. Pat provides an overview of data centers, explaining that they are essentially industrial-scale computer rooms that generate immense amounts of heat from the servers and need precise environmental controls. CRAC units are specialized air conditioning systems designed to maintain the temperature and humidity within tight parameters suitable for electronic equipment. Unlike typical comfort cooling, CRAC units supply air around 70°F to avoid excessive dehumidification. Humidity control is crucial, often requiring supplemental humidifiers or dehumidifiers. Pat discusses common configurations like air-cooled direct expansion (DX) units as well as chilled water systems with computer room air handlers (CRAHs). Redundancy i

  • Rack Refrigeration Class Part 2

    11/06/2024 Duration: 01h37min

    In Part 2 of the Rack Refrigeration Class at Kalos Services, Matthew Taylor discusses safeties, service, and more. Part 1 focuses more on the basic refrigeration circuit of a rack refrigeration system. When safeties are piped together, we have to keep in mind that they're a bit more complex than most HVAC refrigeration systems, especially when it comes to the oil side. All of these safeties and their proper installation can be located on the wiring diagrams. Safeties often respond to pressure, both in the refrigerant circuit and the oil circuit, but they may also respond to amperage or temperature. Each compressor on a rack has its own safety controls, but all compressor safeties should be wired in series. Overloads may measure temperature or amperage and break the circuit if it detects unsafe conditions. We also deploy demand cooling strategies to cool the compressor and help control compression ratios. We can also control capacity with staging strategies. Mechanical controls may be able to communicate with

  • What's your summer triage strategy w/ Kevin Hart

    07/06/2024 Duration: 40min

    This episode dives into an interesting and pragmatic discussion about how HVAC contractors can better balance their workload throughout the year. Kevin from Haven shares insights from observing HVAC businesses across the country and how some are taking a more strategic approach to triaging work. The main idea is to get systems up and running in the peak summer months when demand is highest, while also collecting data and making notes for more in-depth commissioning, ductwork upgrades, IAQ improvements, etc. that can be tackled in the fall "shoulder season." The hosts discuss the market forces that drive the typical reactive cycle - consumers waiting until systems fail to call for service, companies prioritizing new equipment installs when demand is high to boost revenue, etc. However, they propose a model where contractors are more proactive about maintenance, communication, and expectation-setting. Install the right-sized equipment over the summer, document issues to revisit later, use data loggers to analyz

  • Toasters, Desk Chairs and Socrates w/ Ty Brannaman

    06/06/2024 Duration: 51min

    In this insightful episode of the HVAC School Podcast, Ty Brannaman, an exceptional educator and trainer, shares his unique approach to making learning not just effective but also engaging and memorable. He delves into the art of connecting with students, unlocking their curiosity, and fostering a love for learning. Ty emphasizes the importance of understanding that not all students learn in the same way. He advocates for finding creative ways to capture their attention and spark their interest, whether through hands-on experiments, relatable analogies, or thought-provoking demonstrations. By tapping into students' existing experiences and curiosities, Ty creates an environment where learning becomes an exciting adventure rather than a chore. One of the key takeaways from the conversation is the power of the Socratic method. Ty encourages educators to ask questions that challenge students' assumptions and encourage them to think critically about the subject matter. By fostering a sense of exploration and

  • Rack Refrigeration Class Part 1

    04/06/2024 Duration: 01h39min

    This podcast episode is Part 1 of a Kalos class on rack refrigeration given by Matthew Taylor. This first segment focuses on the basic refrigerant circuit and oil management of a parallel rack system, common in market refrigeration. Parallel racks follow the same general process as any other compression refrigeration system. However, they contain multiple compressors on a single rack. These systems have multiple suction lines that tie into one single suction header that feeds into multiple compressors. The suction side of the piping is usually a long distance with varying elevations; risers are vertical stretches of piping that carry oil and refrigerant up and pose a challenge for oil return. The compressor takes low-pressure vapor on the suction side and turns it into high-pressure vapor on the discharge side. From there, the condenser rejects heat from the refrigerant, which brings the superheated vapor down to saturation temperature and further rejects heat to make the refrigerant fully liquid (subcooled).

  • What is Standard 310? w/ Eric Kaiser & Chris Hughes

    30/05/2024 Duration: 01h10s

    Standard 310 is a technical workflow created by ACCA, ResNet, and ANSI for grading the installation of HVAC systems, typically in new home construction. It plays a crucial role in obtaining Energy Star certification, which can qualify homeowners for tax credits under the Inflation Reduction Act. The five steps of Standard 310 are design review, duct leakage test, total system airflow, blower fan watt draw, and refrigerant charge verification. In this podcast episode, host Bryan Orr is joined by guests Chris Hughes and Eric Kaiser to discuss Standard 310 and its implications for HVAC contractors. The standard aims to ensure that HVAC systems are installed correctly and operate as designed. The process involves a third-party HERS rater conducting various tests and measurements, which contractors need to be prepared for. Proper duct sealing, airflow settings, and refrigerant charging are critical for passing the assessments. One of the challenging aspects highlighted is the refrigerant charge verification step.

  • Q&A - Kitchen Exhaust and Makeup Air - Short #197

    28/05/2024 Duration: 07min

    In this short Q&A podcast episode, Bryan answers Gunther's question about kitchen exhaust and makeup air. Gunther asked if there were any studies that showed that makeup air should come very close to the hood to avoid infiltration. He also asked how to educate others who push back against the idea, particularly in kitchen exhaust systems of around 600 CFM. Commercial facilities, especially restaurants, bring in makeup air to balance out the air being exhausted. There are costs associated with makeup air, but there are plenty of valid reasons to add it to residential structures. Being able to control the makeup air allows us to control where we bring air in from (especially when it comes to drawing in humid air or dirty attic air from gaps and cracks, particularly in vented attics). Open-combustion appliances in the building envelope are also prone to backdrafting if the structure is under negative pressure. The structure is also more likely to have its dryer vents experience leaks under negative pressure.

  • Duct Leaks - Measuring, Preventing & Repairing w/ Sam Myers

    23/05/2024 Duration: 42min

    This episode featured Bryan Orr interviewing Sam Myers, the building science consultant at Retrotec. Retrotec manufactures products like blower doors and duct testers for measuring air tightness and leakage in buildings. Sam discussed his role at Retrotec, which involves training contractors on using their tools properly, product design, software testing, presenting at conferences, and running trade show booths. He talked about the demanding travel schedule this requires but also the rewards of educating the industry. The main topic was duct leakage testing - why it's important, how it's done, interpreting the results, and investigating and fixing duct leaks when problems are found. Sam explained that while a duct leakage test provides a number, that number alone doesn't indicate if the leakage is acceptable or problematic. However, it points technicians in the right direction for further investigating issues like comfort problems, indoor air quality concerns, or high energy bills. He provided tips on using t